| Sign In | Join Free | My entremaqueros.com |
|
Model Number : ERX
Refrigerant : R134a/R407C/R22/R410A
Packaging Details : Standard export package
MOQ : 1PCS
Delivery Time : 20-35 working days
Operating power : 380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V
Brand Name : COOLNET
Product Type : All-in-one data center
Payment Terms : L/C,T/T
Power : 3-30kv
Certification : CE ISO
Application area : Network closets or telecom sites , Edge Computing
Price : USD3000-10000/PCS
Cabinet type : 26U 42U
Supply Ability : 200 SETS PER MONTH
Enclosed cabinet : Glass door
Place of Origin : CHINA
Voltage : 380v/220v,110-220v/50-60Hz,220V/50Hz
| Attribute | Value |
|---|---|
| Product Type | All-in-one data center |
| Refrigerant | R134a/R407C/R22/R410A |
| Application area | Network closets or telecom sites, Edge Computing |
| Voltage | 380v/220v,110-220v/50-60Hz,220V/50Hz |
| Operating power | 380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V |
| Cabinet type | 26U 42U |
| Power | 3-30kv |
| Enclosed cabinet | Glass door |
| Series | Conventional Air Conditioning Version |
|---|---|
| Power Supply and Distribution | |
| UPS Capacity | 3KVA | 6KVA | 10KVA | 20KVA |
| Power factor | 0.8 | 0.8 | 0.8 | 0.9 |
| Total power input | 220V/40A | 220V/63A | 220V/125A | 380V/125A |
| Height | 4U | 4U | 4U | 6U |
| Lightning protection | C class |
| Others | ATS Module (optional) |
| Cabinet | |
| Recommended number of IT cabinets | 1 | 2 | 3 | 5 |
| Available space | 28U | 33U+42U | 29U+2*42U | 30U+4*42U |
| Number of PDUs in a single rack | 1*8bit10A | 1*12bit10A | 1*(12bit10A+4bit16A) |
| Closed aisle | Fully enclosed cold and hot aisle |
| Emergency ventilation | Fan-type emergency ventilation system, supports maximum 5KW heat dissipation, automatic start and stop |
| IT space expansion | Standard IT cabinet with 42U usable space (optional) |
| Refrigeration | |
| Type | Rack mount | In row | In row | In row |
| Cooling Capacity (KW) | 3.5 | 7.5 | 12.5 | 2*12.5 |
| Sensible heat ratio | 1 |
| System | Compression system + EC fan |
| Monitoring | |
| Monitoring volume | UPS, Power distribution, AC, Water leakage, Temperature & Humidity, Smoke, Door sensor |
| Function | Data collection and storage, alarm management, energy consumption analysis, remote access, sound and light alarm (optional), SMS alarm (optional), APP (optional) |
| Display | 10-inch Touch screen |
| Fire Protection | |
| Heptafluoropropane | 1U Rack-mounted gas fire extinguishing system (optional) |
| Battery | |
| Standard number of batteries | 8 | 16 | 16 | 20 |
| Backup power for 15 minutes | 2U Battery Pack | 3U Battery Pack | 6U Battery Pack |
| Backup power for 40 minutes | External 20100A/12V |
| Backup power for 90 minutes | Can be replaced with high-capacity batteries or increase the number of battery packs (not more than 4) |
| Size | |
| W*D*H-mm | 600*1200*2000 | 1500*1200*2000 | 2100*1200*2000 | 3600*1200*2000 |
| Environment | |
| Environment temperature | 0~45℃ |
| Environment humidity | Relative humidity 0-95%, no condensation |
| Altitude | <1000m, The excess part is derated according to relevant standards |
|
|
Prefabricated Data Center Facilities Offering Standardized Components Streamlined Assembly and Optimized Space Utilization Images |